This guide will walk through the steps to replace the shuttle spring plate on the Milwaukee M12 2407-20.

What you need

Tools

    1. Milwaukee M12 2407-20 Shuttle Spring Plate Replacement, Outer Casing: step 1, image 1 of 1
      • Remove each of the seven 14mm Pan Hd. T-10 ST screws on one side of the housing assembly using the T10 screwdriver.

      Ask FixBot

      Add Comment

    2. Milwaukee M12 2407-20 Shuttle Spring Plate Replacement: step 2, image 1 of 1
      • Remove metal clip located at the base of the drill, where the battery is to be inserted.

      • You may need to use a spudger if the clip is too difficult to remove with your fingers.

      Ask FixBot

      Add Comment

    1. Milwaukee M12 2407-20 Shuttle Spring Plate Replacement, Shuttle Spring Plate: step 3, image 1 of 3 Milwaukee M12 2407-20 Shuttle Spring Plate Replacement, Shuttle Spring Plate: step 3, image 2 of 3 Milwaukee M12 2407-20 Shuttle Spring Plate Replacement, Shuttle Spring Plate: step 3, image 3 of 3
      • Use both hands to lift and remove the gear case assembly from the shell casing.

      • Set the gear case assembly aside.

      Ask FixBot

      Add Comment

    2. Milwaukee M12 2407-20 Shuttle Spring Plate Replacement: step 4, image 1 of 2 Milwaukee M12 2407-20 Shuttle Spring Plate Replacement: step 4, image 2 of 2
      • Remove the forward/reversing shuttle to gain access to the spring plate.

      Ask FixBot

      Add Comment

    3. Milwaukee M12 2407-20 Shuttle Spring Plate Replacement: step 5, image 1 of 1
      • Remove the spring plate and insert replacement spring plate.

      Ask FixBot

      Add Comment

Conclusion

To reassemble your device, follow these instructions in reverse order.