What you need

  1. Hitachi CP-X2011N Bulb Replacement, Lightbulb: step 1, image 1 of 1
    • Unscrew the single captive screw that secures the lamp cover.

    • The screw will not come off the lid completely.

  2. Hitachi CP-X2011N Bulb Replacement: step 2, image 1 of 1
    • Slide the lid away from the body of the projector until it stops. Then, lift the lid upwards to remove it.

  3. Hitachi CP-X2011N Bulb Replacement: step 3, image 1 of 1
    • Unscrew the three captive silver screws on the top of the lamp housing.

    • These screws should not be removed from the housing.

  4. Hitachi CP-X2011N Bulb Replacement: step 4, image 1 of 1
    • Pull the lamp up and out.

    • This may take some gentle force.

Conclusion

To reassemble your device, follow the above steps in reverse order.