<item>
<title><![CDATA[Verathon Glidescope Titanium: Verathon glidescope titanium working]]></title>
<description><![CDATA[<p><strong><em>How does it works</em></strong></p>

<p>⟐ Answered June 17, 2025 at 20:11 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/904051/Verathon+glidescope+titanium+working</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/904051</guid>
<pubDate>Tue, 17 Jun 2025 20:11:13 -0700</pubDate>
</item>
<item>
<title><![CDATA[Valleylab Force FX-C: show generator code 4 instead of 1]]></title>
<description><![CDATA[<p>hey, fellas need help with vellylab force fx c esu as it shows the generator code 4 instead of 1 . after calibration, the error 212 remains constant.</p>

<p>⟐ Commented May 08, 2025 at 22:43 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/863822/show+generator+code+4+instead+of+1</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/863822</guid>
<pubDate>Thu, 08 May 2025 22:43:21 -0700</pubDate>
</item>
<item>
<title><![CDATA[Electrosurgical Generator: Why is the neutral plate of Electrosurgical generator Keep alarming?]]></title>
<description><![CDATA[<p>Neutral plate error showing on the screen even after I checked the plate it's  self and the internal connection. As soon as you connect the neutral plate, it seems to work correctly but after few seconds the error will occurred.</p>

<p>⟐ Commented April 02, 2024 at 8:37 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/843003/Why+is+the+neutral+plate+of+Electrosurgical+generator+Keep+alarming</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/843003</guid>
<pubDate>Tue, 02 Apr 2024 08:37:35 -0700</pubDate>
</item>
<item>
<title><![CDATA[Berchtold Operating Table: Operon D830 - No Drive Function]]></title>
<description><![CDATA[<p>I have an Operon B830 with no drive function. Upon pressing the drive function both the service light flashes (intermittent) and the limit switch light flashes. Anyone familiar with or seen this issue before? Every other function seems to work.</p>

<p>⟐ Answered May 06, 2021 at 19:03 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/683183/Operon+D830+-+No+Drive+Function</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/683183</guid>
<pubDate>Thu, 06 May 2021 19:03:36 -0700</pubDate>
</item>
<item>
<title><![CDATA[Olympus OEV Monitor: Why is the unit shuts down after 3 minutes?]]></title>
<description><![CDATA[<p>Why is the unit shuts down after 3 minutes? And Fan is not running.Voltages present in the Fan Connectors.</p>]]></description>
<link>https://www.ifixit.com/Answers/View/946921/Why+is+the+unit+shuts+down+after+3+minutes</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/946921</guid>
<pubDate>Thu, 26 Mar 2026 05:00:39 -0700</pubDate>
</item>
<item>
<title><![CDATA[Alsa Excell 350 MCDSe: Excell alsa 350 has error 39 during self test]]></title>
<description><![CDATA[<p>Dear all</p>

<p>The unit is giving error 39 . As it is Error in the internal dummy load used during the self test .</p>

<p>Could any one help to repair this fault</p>

<p>Thank you</p>]]></description>
<link>https://www.ifixit.com/Answers/View/928843/Excell+alsa+350+has+error+39+during+self+test</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/928843</guid>
<pubDate>Tue, 02 Dec 2025 03:57:09 -0700</pubDate>
</item>
<item>
<title><![CDATA[Laparoscopy: Laparoscopy video system Hologic Omni 4K]]></title>
<description><![CDATA[<p>I have a problem with hologic Omni 4K</p>

<p>Vidro system</p>

<p>2001 could no t start recording</p>

<p>Please try again</p>

<p>i ‘m looking for the service password</p>

<p>Thank you</p>

<p>Miguel Chavira</p>]]></description>
<link>https://www.ifixit.com/Answers/View/896273/Laparoscopy+video+system+Hologic+Omni+4K</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/896273</guid>
<pubDate>Wed, 16 Apr 2025 05:19:32 -0700</pubDate>
</item>
<item>
<title><![CDATA[Karl Storz Laryngoscopy: Replacing Battery in CMAC Pocket Scope]]></title>
<description><![CDATA[<p>My battery is losing charge quickly and Storz will not service as it's older and they no longer support it. How can I replace the battery?</p>

<p>⟐ Commented July 28, 2023 at 16:40 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/804174/Replacing+Battery+in+CMAC+Pocket+Scope</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/804174</guid>
<pubDate>Fri, 28 Jul 2023 16:40:57 -0700</pubDate>
</item>
<item>
<title><![CDATA[ConMed System 7550: foot control tones, but there is no output]]></title>
<description><![CDATA[<p>If I use the pencil, I get output, if I use the foot control, there is none, no cut, no coag. it tones as if it is working, there is no errors, but my sim shows no output.</p>]]></description>
<link>https://www.ifixit.com/Answers/View/759676/foot+control+tones,+but+there+is+no+output</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/759676</guid>
<pubDate>Thu, 15 Dec 2022 06:46:13 -0700</pubDate>
</item>
<item>
<title><![CDATA[Steris 5085: How to calibrate heights limit on the table]]></title>
<description><![CDATA[<p>Hi, I need to calibrate height limit for 5085. Shroud get disengaged and keeps braking welding</p>

<div class="clearer"></div><div class="headerContainer"><h3 id="Section_Update_08_24_Num_2022" class="header">Update (08/24/2022)</h3></div>

<p>Steris 5085 SRT, Surgical Table</p>

<p>⟐ Edited by author August 24, 2022 at 6:29 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/744896/How+to+calibrate+heights+limit+on+the+table</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/744896</guid>
<pubDate>Wed, 24 Aug 2022 06:29:42 -0700</pubDate>
</item>
<item>
<title><![CDATA[Surgical Equipment: Code for Drager Julian]]></title>
<description><![CDATA[<p>I need a code for a Drager Julian to enable me change from German to english</p>]]></description>
<link>https://www.ifixit.com/Answers/View/701953/Code+for+Drager+Julian</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/701953</guid>
<pubDate>Tue, 10 Aug 2021 10:19:54 -0700</pubDate>
</item>
<item>
<title><![CDATA[OR Solutions ORS-1075HS 1058HS Hush Slush: Auto Stir only goes up/down once then stops]]></title>
<description><![CDATA[<p>Auto Stir option goes up/down once on power up then stops and switch light goes out.  Shouldn’t this continue to cycle up/down while switch is on?</p>]]></description>
<link>https://www.ifixit.com/Answers/View/695016/Auto+Stir+only+goes+up-down+once+then+stops</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/695016</guid>
<pubDate>Mon, 07 Jun 2021 12:49:01 -0700</pubDate>
</item>