<item>
<title><![CDATA[Clinitek Urine Analyzer: Why is my clinitek urine analyzer not turning on?]]></title>
<description><![CDATA[<p>My device was working yesterday, but a blackout occurred after and now it is not turning on even when plugged and used different power outlets to turn it on.</p>

<p>⟐ Answered April 03, 2026 at 23:07 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/948460/Why+is+my+clinitek+urine+analyzer+not+turning+on</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/948460</guid>
<pubDate>Fri, 03 Apr 2026 23:07:58 -0700</pubDate>
</item>
<item>
<title><![CDATA[Prosthetics: How do I take my shock off my prosthetic leg]]></title>
<description><![CDATA[<p>How do I get my shock off my prosthetic leg</p>

<p>⟐ Commented April 02, 2026 at 16:12 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/948207/How+do+I+take+my+shock+off+my+prosthetic+leg</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/948207</guid>
<pubDate>Thu, 02 Apr 2026 16:12:55 -0700</pubDate>
</item>
<item>
<title><![CDATA[Acutemp Hemacool HMC-MIL-1: Why cant I use the key pad to type in serial number?]]></title>
<description><![CDATA[<p>I had to wire a new battery harness and replace the fuses and the cord and finally got power and the key pad only lets number go down when trying to set up. Tried the combos every way but i cant get it to select and i cant use until i set type in serial number</p>]]></description>
<link>https://www.ifixit.com/Answers/View/947940/Why+cant+I+use+the+key+pad+to+type+in+serial+number</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/947940</guid>
<pubDate>Tue, 31 Mar 2026 22:31:12 -0700</pubDate>
</item>
<item>
<title><![CDATA[Olympus OEV Monitor: Why is the unit shuts down after 3 minutes?]]></title>
<description><![CDATA[<p>Why is the unit shuts down after 3 minutes? And Fan is not running.Voltages present in the Fan Connectors.</p>]]></description>
<link>https://www.ifixit.com/Answers/View/946921/Why+is+the+unit+shuts+down+after+3+minutes</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/946921</guid>
<pubDate>Thu, 26 Mar 2026 05:00:39 -0700</pubDate>
</item>
<item>
<title><![CDATA[Medical Power Strip: 6power strip won't work or steady s]]></title>
<description><![CDATA[<p>Why won't 3 of 6 outlets of my power strip work</p>

<p>⟐ Commented March 17, 2026 at 1:41 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/945394/6power+strip+won&#039;t+work+or+steady+s</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/945394</guid>
<pubDate>Tue, 17 Mar 2026 01:41:49 -0700</pubDate>
</item>
<item>
<title><![CDATA[Welch Allyn GSI TM262 Auto Tymp: repair air pump internal]]></title>
<description><![CDATA[<p>the tympanometry internal air pump has a worn out internal rubber bladder. if the part can be identified and replaced rest of tymp works.  would like to repair and donate as a screening device to a free clinic. would appreciate advice and or help</p>

<p>⟐ Answered March 14, 2026 at 21:48 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944964/repair+air+pump+internal</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944964</guid>
<pubDate>Sat, 14 Mar 2026 21:48:52 -0700</pubDate>
</item>
<item>
<title><![CDATA[Life Fitness Scifit Pro2: Knee and handles are hitting when using both.]]></title>
<description><![CDATA[<p>My knees and the handles when using both hit.</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944940/Knee+and+handles+are+hitting+when+using+both.</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944940</guid>
<pubDate>Sat, 14 Mar 2026 09:02:35 -0700</pubDate>
</item>
<item>
<title><![CDATA[Perfecto 2 Oxygen Concentrator: unit shuts down after 30 seconds]]></title>
<description><![CDATA[<p>unit shuts down after 30 seconds and has a flashing red light and a green light in sequence</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944865/unit+shuts+down+after+30+seconds</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944865</guid>
<pubDate>Fri, 13 Mar 2026 21:57:56 -0700</pubDate>
</item>
<item>
<title><![CDATA[GE Corometrics 118: Where are the Corometrics Model 118 Service Manual Parts 3 and 5?]]></title>
<description><![CDATA[<p>Where are the Corometrics Model 118 Service Manual Parts 3 and 5?</p>

<p>You have parts 1, 2, 4, 6, and 7.</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944799/Where+are+the+Corometrics+Model+118+Service+Manual+Parts+3+and+5</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944799</guid>
<pubDate>Fri, 13 Mar 2026 12:02:06 -0700</pubDate>
</item>
<item>
<title><![CDATA[Stryker FL28C: Brakes do not lock]]></title>
<description><![CDATA[<p>How do you fix the brakes on this unit. The wheels just click but do not lock.</p>

<p>⟐ Commented March 12, 2026 at 18:35 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944613/Brakes+do+not+lock</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944613</guid>
<pubDate>Thu, 12 Mar 2026 18:35:56 -0700</pubDate>
</item>
<item>
<title><![CDATA[Medical Support Equipment: Oxygen portable concentrator settings]]></title>
<description><![CDATA[<p>How to reset portable O2 concentrator</p>

<p>⟐ Answered March 11, 2026 at 20:12 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944484/Oxygen+portable+concentrator+settings</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944484</guid>
<pubDate>Wed, 11 Mar 2026 20:12:23 -0700</pubDate>
</item>
<item>
<title><![CDATA[Samsung Ultrasound WS80A: Uređaj se gasi nakon par minuta rada.]]></title>
<description><![CDATA[<p>Prije gašenja zatreperi taaster za paljenje i gašenje na kontrolnom pultu .Nakon toga uređaj je totalno mrtav.Na napojnoj jedinici svijetli zelena led.Nakon nekoliko desetina minuta može opet da se pokrene,ali opet nakon kratkog vremena se ugasi.</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944236/Ure%C4%91aj+se+gasi+nakon+par+minuta+rada.</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944236</guid>
<pubDate>Tue, 10 Mar 2026 12:28:02 -0700</pubDate>
</item>
<item>
<title><![CDATA[BCI Capnocheck Plus: Anyone have the BCI analog output cable pinout diagram?]]></title>
<description><![CDATA[<p>I need the above named output cable, either 3 or 4 channel variety.</p>

<div class="clearer"></div><div class="headerContainer"><h2 id="Section__BCI_4_Channel_Distance_Analog_Output_Cable_Polysomnography_for_Capnocheck_Sleep" class="header"><strong>BCI 4 Channel/Distance Analog Output Cable (Polysomnography) for Capnocheck Sleep</strong></h2></div>

<p><strong>Thanks</strong></p>

<p>⟐ Answer edited March 10, 2026 at 12:18 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/889047/Anyone+have+the+BCI+analog+output+cable+pinout+diagram</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/889047</guid>
<pubDate>Tue, 10 Mar 2026 12:18:42 -0700</pubDate>
</item>
<item>
<title><![CDATA[General Electric Voluson S8 Voluson S6: Why is my ultrasound not booting]]></title>
<description><![CDATA[<p>My ultrasound is not booting to the end</p>]]></description>
<link>https://www.ifixit.com/Answers/View/944149/Why+is+my+ultrasound+not+booting</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/944149</guid>
<pubDate>Tue, 10 Mar 2026 03:42:36 -0700</pubDate>
</item>
<item>
<title><![CDATA[Pride Mobility Jazzy 600 Power Wheelchair: The power indecator doesn't decrease over time of operation.]]></title>
<description><![CDATA[<p>It reads full power then after a while of operation it reads empty, but still works usually I turn unit off wait a minute turn on again. Reads ok till it isn't. Again I reset. When it does this I don't idle when not moving I turn off.  I wish I had a better more mechanical register maybe connecting through charger port.</p>

<p>Any one have a clue of what im talking about?</p>]]></description>
<link>https://www.ifixit.com/Answers/View/943240/The+power+indecator+doesn&#039;t+decrease+over+time+of+operation.</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/943240</guid>
<pubDate>Wed, 04 Mar 2026 11:09:23 -0700</pubDate>
</item>
<item>
<title><![CDATA[Welch Allyn Vital Signs: My ophthalmoscope is not charging]]></title>
<description><![CDATA[<p>When I attach my opgthalmoscope to the charging dock it keeps on flashing lights fromcthe globe head but does not charge or turns on when I use it</p>

<p>⟐ Answered March 04, 2026 at 0:23 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/943160/My+ophthalmoscope+is+not+charging</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/943160</guid>
<pubDate>Wed, 04 Mar 2026 00:23:37 -0700</pubDate>
</item>
<item>
<title><![CDATA[Game Ready Cold Therapy: Unit shuts down after a minute.]]></title>
<description><![CDATA[<p>The Game Ready worked perfectly yesterday. Mow it shuts down after a minute. I can't set the timer for longer than that.</p>

<p>⟐ Commented March 01, 2026 at 7:49 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/942795/Unit+shuts+down+after+a+minute.</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/942795</guid>
<pubDate>Sun, 01 Mar 2026 07:49:30 -0700</pubDate>
</item>
<item>
<title><![CDATA[Philips M3000A: Table move ment problem]]></title>
<description><![CDATA[<p>Table move some noice crates</p>]]></description>
<link>https://www.ifixit.com/Answers/View/942232/Table+move+ment+problem</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/942232</guid>
<pubDate>Wed, 25 Feb 2026 11:19:13 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics CPAP: Relentless reboots, but runs fine once started.]]></title>
<description><![CDATA[<p>Worked fine originally after receiving donated used unit. After a few months, pushing the start button would beep, display logo, display FW version, display flow rate, spin up the blower, then go dark and start the cycle over.</p>

<p>Eventually, the blower stays on and it runs through my sleep cycle like nothing ever happened. This normal state might be reached after 20 restarts. Also, after some random restart count it will stay off, requiring a replug power-up to begin the restart cycle anew, up to three replugs and about 20min being a worst case. Best case it fires up after about 10 restarts. <strong>I just realized I've never checked the display before a replug so I'll do that tonight. I checked, it goes blank when it's all beeped out.</strong></p>

<p>All functions, settings, and input buttons work as expected after running, including the humidifier. No leaks or bad gaskets, blower spins freely. About to replace PCA button battery but the old one had good voltage. Contact cleaner used when resetting every jack. Power supply good. Filters clean. I'll be rechecking all of these things one more time plus a picky board inspection, but I don't expect to find a problem at component level.</p>

<p>I can't imagine what kind of consistent, repeatable error could exist with no fault found. It behaves as if some sensor feedback is telling the algorithm that it can't run or start. Considering getting a serial adapter module and downloading the tech software but I have never seen an error code on the display.</p>

<p>Subjectively, 3 things I find interesting are:</p>

<p>1) the restart blower puff seems to gain volume and power up to the running state; if it dwindles or remains lame it's likely restart attempts will stop until a replug</p>

<p>2) dial digit 4 is slightly dim, but lights as expected</p>

<p>3) I checked the button battery voltage in situ, and it crept upwards. I've never seen this before but some reading tells me their may be an intentional capacitor storage, maybe to kick start the blower or something.</p>

<p>I could talk about this all night, given that a new machine will run me $1400CDN.</p>

<p>⟐ Commented February 22, 2026 at 23:03 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/941023/Relentless+reboots,+but+runs+fine+once+started.</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/941023</guid>
<pubDate>Sun, 22 Feb 2026 23:03:35 -0700</pubDate>
</item>
<item>
<title><![CDATA[Siemens CT Scanner: Unable to start the checkup procedure, scan aborting on its own]]></title>
<description><![CDATA[<p>What should I do now ? The system shows &quot; Defective Channel Correction&quot; abort by error</p>

<p>⟐ Answered February 14, 2026 at 2:57 MST</p>]]></description>
<link>https://www.ifixit.com/Answers/View/925699/Unable+to+start+the+checkup+procedure,+scan+aborting+on+its+own</link>
<guid isPermaLink="false" >https://www.ifixit.com/Answers/View/925699</guid>
<pubDate>Sat, 14 Feb 2026 02:57:05 -0700</pubDate>